smartctl 5.41 2011-06-09 r3365 [i686-w64-mingw32-2008r2(64)-sp1] (sf-win32-5.41-1)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Device Model:     ST31000524AS
Serial Number:    9VPFF4E9
LU WWN Device Id: 5 000c50 040161565
Firmware Version: JC4B
User Capacity:    1,000,204,886,016 bytes [1.00 TB]
Sector Size:      512 bytes logical/physical
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   8
ATA Standard is:  ATA-8-ACS revision 4
Local Time is:    Mon Nov 17 11:24:08 2014 GMTST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82)	Offline data collection activity
					was completed without error.
					Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0)	The previous self-test routine completed
					without error or no self-test has ever 
					been run.
Total time to complete Offline 
data collection: 		(  600) seconds.
Offline data collection
capabilities: 			 (0x7b) SMART execute Offline immediate.
					Auto Offline data collection on/off support.
					Suspend Offline collection upon new
					command.
					Offline surface scan supported.
					Self-test supported.
					Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					General Purpose Logging supported.
Short self-test routine 
recommended polling time: 	 (   1) minutes.
Extended self-test routine
recommended polling time: 	 ( 168) minutes.
Conveyance self-test routine
recommended polling time: 	 (   2) minutes.
SCT capabilities: 	       (0x103f)	SCT Status supported.
					SCT Error Recovery Control supported.
					SCT Feature Control supported.
					SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   106   087   006    Pre-fail  Always       -       11368514
  3 Spin_Up_Time            0x0003   100   100   000    Pre-fail  Always       -       0
  4 Start_Stop_Count        0x0032   100   100   020    Old_age   Always       -       400
  5 Reallocated_Sector_Ct   0x0033   100   100   036    Pre-fail  Always       -       0
  7 Seek_Error_Rate         0x000f   087   060   030    Pre-fail  Always       -       610331797
  9 Power_On_Hours          0x0032   076   076   000    Old_age   Always       -       21217
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   100   100   020    Old_age   Always       -       432
183 Runtime_Bad_Block       0x0032   100   100   000    Old_age   Always       -       0
184 End-to-End_Error        0x0032   100   100   099    Old_age   Always       -       0
187 Reported_Uncorrect      0x0032   001   001   000    Old_age   Always       -       1089
188 Command_Timeout         0x0032   100   100   000    Old_age   Always       -       0
189 High_Fly_Writes         0x003a   100   100   000    Old_age   Always       -       0
190 Airflow_Temperature_Cel 0x0022   076   052   045    Old_age   Always       -       24 (Min/Max 19/30)
194 Temperature_Celsius     0x0022   024   048   000    Old_age   Always       -       24 (0 15 0 0)
195 Hardware_ECC_Recovered  0x001a   039   025   000    Old_age   Always       -       11368514
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       -       0
240 Head_Flying_Hours       0x0000   100   253   000    Old_age   Offline      -       107623290525012
241 Total_LBAs_Written      0x0000   100   253   000    Old_age   Offline      -       1446367986
242 Total_LBAs_Read         0x0000   100   253   000    Old_age   Offline      -       1703117438

SMART Error Log Version: 1
ATA Error Count: 1081 (device log contains only the most recent five errors)
	CR = Command Register [HEX]
	FR = Features Register [HEX]
	SC = Sector Count Register [HEX]
	SN = Sector Number Register [HEX]
	CL = Cylinder Low Register [HEX]
	CH = Cylinder High Register [HEX]
	DH = Device/Head Register [HEX]
	DC = Device Command Register [HEX]
	ER = Error register [HEX]
	ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 1081 occurred at disk power-on lifetime: 21185 hours (882 days + 17 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 ff ff ff 0f  Error: UNC at LBA = 0x0fffffff = 268435455

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 00 40 ff ff ff 4f 00  11d+11:53:35.873  READ FPDMA QUEUED
  61 00 02 fb 7e 40 4d 00  11d+11:53:35.872  WRITE FPDMA QUEUED
  61 00 08 ff ff ff 4f 00  11d+11:53:35.872  WRITE FPDMA QUEUED
  61 00 48 e4 d1 60 40 00  11d+11:53:35.872  WRITE FPDMA QUEUED
  b0 da 00 00 4f c2 40 00  11d+11:53:35.850  SMART RETURN STATUS

Error 1080 occurred at disk power-on lifetime: 21185 hours (882 days + 17 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 ff ff ff 0f  Error: WP at LBA = 0x0fffffff = 268435455

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  61 00 06 ff ff ff 4f 00  11d+11:53:32.699  WRITE FPDMA QUEUED
  61 00 0a ff ff ff 4f 00  11d+11:53:32.699  WRITE FPDMA QUEUED
  61 00 0d ff ff ff 4f 00  11d+11:53:32.698  WRITE FPDMA QUEUED
  61 00 21 ff ff ff 4f 00  11d+11:53:32.698  WRITE FPDMA QUEUED
  61 00 04 ff ff ff 4f 00  11d+11:53:32.698  WRITE FPDMA QUEUED

Error 1079 occurred at disk power-on lifetime: 21185 hours (882 days + 17 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 ff ff ff 0f  Error: WP at LBA = 0x0fffffff = 268435455

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  61 00 08 5c e9 64 40 00  11d+11:53:29.807  WRITE FPDMA QUEUED
  61 00 08 54 e2 5f 40 00  11d+11:53:29.806  WRITE FPDMA QUEUED
  61 00 08 64 0b 64 40 00  11d+11:53:29.806  WRITE FPDMA QUEUED
  61 00 08 34 06 64 40 00  11d+11:53:29.805  WRITE FPDMA QUEUED
  61 00 08 dc d1 60 40 00  11d+11:53:29.804  WRITE FPDMA QUEUED

Error 1078 occurred at disk power-on lifetime: 21185 hours (882 days + 17 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 ff ff ff 0f  Error: WP at LBA = 0x0fffffff = 268435455

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  61 00 08 bc b8 39 42 00  11d+11:53:26.857  WRITE FPDMA QUEUED
  61 00 08 80 29 df 4c 00  11d+11:53:26.857  WRITE FPDMA QUEUED
  61 00 34 c4 b8 39 42 00  11d+11:53:26.855  WRITE FPDMA QUEUED
  61 00 08 98 69 e0 4c 00  11d+11:53:26.855  WRITE FPDMA QUEUED
  61 00 09 3c f8 fe 40 00  11d+11:53:26.854  WRITE FPDMA QUEUED

Error 1077 occurred at disk power-on lifetime: 21185 hours (882 days + 17 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 ff ff ff 0f  Error: WP at LBA = 0x0fffffff = 268435455

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  61 00 08 78 29 df 4c 00  11d+11:53:23.707  WRITE FPDMA QUEUED
  61 00 01 03 2c 39 4d 00  11d+11:53:23.707  WRITE FPDMA QUEUED
  61 00 08 80 29 df 4c 00  11d+11:53:23.705  WRITE FPDMA QUEUED
  61 00 20 20 80 ae 4e 00  11d+11:53:23.700  WRITE FPDMA QUEUED
  61 00 20 40 7d ae 4e 00  11d+11:53:23.700  WRITE FPDMA QUEUED

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Extended offline    Interrupted (host reset)      00%     17470         -
# 2  Short offline       Completed without error       00%     17461         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.