File: D:/bin/scripts/python/smartctl/log_sdc.txt
smartctl 6.3 2014-07-26 r3976 [x86_64-w64-mingw32-2008r2-sp1] (sf-6.3-1)
Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: Samsung SSD 850 EVO 500GB
Serial Number: S21JNXAG929947T
LU WWN Device Id: 5 002538 d40554a97
Firmware Version: EMT01B6Q
User Capacity: 500,107,862,016 bytes [500 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Wed Jun 05 05:01:31 2019 GMTDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 0) seconds.
Offline data collection
capabilities: (0x53) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 265) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
9 Power_On_Hours -O--CK 093 093 000 - 31926
12 Power_Cycle_Count -O--CK 098 098 000 - 1402
177 Wear_Leveling_Count PO--C- 098 098 000 - 38
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
190 Airflow_Temperature_Cel -O--CK 052 042 000 - 48
195 Hardware_ECC_Recovered -O-RC- 200 200 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 100 100 000 - 0
235 Unknown_Attribute -O--C- 099 099 000 - 10
241 Total_LBAs_Written -O--CK 099 099 000 - 43150526096
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 1 Comprehensive SMART error log
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa1 SL VS 16 Device vendor specific log
0xa5 SL VS 16 Device vendor specific log
0xce SL VS 16 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
No self-tests have been logged. [To run self-tests, use: smartctl -t]
Warning! SMART Selective Self-Test Log Structure error: invalid SMART checksum.
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
255 0 65535 Read_scanning was never started
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 256 (0x0100)
SCT Support Level: 1
Device State: SCT command executing in background (5)
Current Temperature: 45 Celsius
Power Cycle Min/Max Temperature: 29/45 Celsius
Lifetime Min/Max Temperature: 0/70 Celsius
Under/Over Temperature Limit Count: 4294967295/4294901760
SCT Temperature History Version: 3 (Unknown, should be 2)
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 10 minutes
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: 0/70 Celsius
Temperature History Size (Index): 128 (114)
Index Estimated Time Temperature Celsius
115 2019-06-04 07:50 40 *********************
... ..( 14 skipped). .. *********************
2 2019-06-04 10:20 40 *********************
3 2019-06-04 10:30 41 **********************
... ..( 4 skipped). .. **********************
8 2019-06-04 11:20 41 **********************
9 2019-06-04 11:30 40 *********************
... ..( 6 skipped). .. *********************
16 2019-06-04 12:40 40 *********************
17 2019-06-04 12:50 41 **********************
... ..( 3 skipped). .. **********************
21 2019-06-04 13:30 41 **********************
22 2019-06-04 13:40 40 *********************
23 2019-06-04 13:50 40 *********************
24 2019-06-04 14:00 40 *********************
25 2019-06-04 14:10 41 **********************
... ..( 4 skipped). .. **********************
30 2019-06-04 15:00 41 **********************
31 2019-06-04 15:10 40 *********************
... ..( 3 skipped). .. *********************
35 2019-06-04 15:50 40 *********************
36 2019-06-04 16:00 41 **********************
... ..( 8 skipped). .. **********************
45 2019-06-04 17:30 41 **********************
46 2019-06-04 17:40 40 *********************
... ..( 55 skipped). .. *********************
102 2019-06-05 03:00 40 *********************
103 2019-06-05 03:10 42 ***********************
104 2019-06-05 03:20 42 ***********************
105 2019-06-05 03:30 41 **********************
... ..( 7 skipped). .. **********************
113 2019-06-05 04:50 41 **********************
114 2019-06-05 05:00 45 **************************
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP Log 0x04) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 65535+ Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 28 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC